An automated device to release a desired volume of a liquid from a container

Show simple item record

dc.contributor.author Hasanga, A.H.H.
dc.contributor.author Dharmaratna, W.G.D.
dc.contributor.author Abeywicrama, S.S.
dc.contributor.author Ranatunga, E.M.
dc.date.accessioned 2023-02-15T06:39:31Z
dc.date.available 2023-02-15T06:39:31Z
dc.date.issued 2018-02-15
dc.identifier.issn 1391-8796
dc.identifier.uri http://ir.lib.ruh.ac.lk/xmlui/handle/iruor/11181
dc.description.abstract A simple automated device has been designed and constructed in order to release a desired volume of a liquid from a container. A solenoid valve is used to start and stop the release of liquid quickly. The time period of the solenoid valve kept open, which determines the volume of the released liquid, has been programmed electronically for a predetermined rate of flow of the liquid. This preliminary model was tested with water. The device released water at the average rate of 69.114 ± 0.001ml sec-1. When the machine was programmed to release 550 ml and tested 50 times, 42%, 18% and 16% of the number of measurements were accurate within ±0.1, ±0.2 and ±0.3 ml, respectively and the highest deviation was one measurement with 550.6 ml. By measuring the volume of water released in periods (T) of 1 s to 14 s, each repeating 10 times, and fitting the data, a linear relationship, V=68.301T+8.3795 with r2 = 0.9999 was obtained for overall calibration to release any desired volume. With this calibration, the device was accurate within 0.5% of the desired volume when the released volume is greater than 300 ml. The error is higher at lower volumes, about 2% for releasing 100 ml. The machine can be programmed for other liquids, such as kerosene oil and coconut oil so that the users could select the relevant function. There are several advantages of the machine, such as low manufacturing cost (Rs. 15,000.00), easy to manufacture locally, user friendly, less processing time (14 s to release 1000 ml), sufficiently accurate, and easily repairable. Further improvement of the accuracy is in progress including a mechanism to minimize power fluctuations of the motor. en_US
dc.language.iso en en_US
dc.publisher Faculty of Science, University of Ruhuna, Matara, Sri Lanka en_US
dc.subject Desired liquid volume en_US
dc.subject Automated device en_US
dc.title An automated device to release a desired volume of a liquid from a container en_US
dc.type Article en_US