Use of a Novel Portable Three-Dimensional Imaging System to Measure Limb Volume and Circumference in Patients with Filarial Lymphedema

Show simple item record

dc.contributor.author Yahathugoda, T.C.
dc.contributor.author Weiler, M.J.
dc.contributor.author Ramakrishna Rao
dc.contributor.author De Silva, L.
dc.contributor.author Dixon, J. Brandon
dc.contributor.author Weerasooriya, M.V.
dc.contributor.author Weil, Gary J.
dc.contributor.author Budge, P.J.
dc.date.accessioned 2024-10-08T04:45:37Z
dc.date.available 2024-10-08T04:45:37Z
dc.date.issued 2017-10-16
dc.identifier.citation "Yahathugoda, T.C., Weiler, M., Rao, R., De Silva, L., Dixon, J., Weerasooriya, M.W., Weil, G. and Budge, P. (2017). Use of a novel portable 3D scanner to measure limb volume and circumference in patients with filarial lymphedema. American Journal of Tropical Medicine and Hygiene, 97(6),1836-1842." en_US
dc.identifier.uri http://ir.lib.ruh.ac.lk/handle/iruor/17998
dc.description.abstract The World Health Organization’s Global Program to Eliminate Lymphatic Filariasis (LF) has reduced LF transmission worldwide, but millions remain affected by filarial lymphedema. Tools for clinically monitoring lymphedema in developing nations are limited. We tested a novel, portable, infrared three-dimensional imaging system (3DIS) against water displacement (WD) and tape measurement of limb circumference (TMLC) among patients with filarial leg lymphedema in Galle, Sri Lanka. Outcomes were accuracy and reproducibility of imaging system measurements. In parallel, we also tested the reproducibility of skin thickness ultrasound (STU) measurements. We examined 52 patients (104 limbs) with lymphedema of stages 0–6 (N = 28, 19, 20, 21, 2, 4, and 10, respectively). 3DIS measurements correlated nearly perfectly with WD (r2 = 0.9945) and TMLC values (r2 > 0.9801). The median time required to acquire imaging system measurements for both legs was 2.1 minutes, compared with 17, 7, and 29 minutes, respectively, for WD, TMLC, and STU. Median interexaminer coefficients of variation (CVs) for volume measurements were 1.1% (interquartile range [IQR] 0.5–2.1%) for WD and 1.7% (IQR 1.2–2.4%) for the 3DIS. CVs for circumference measurements were 1.4% (IQR 0.8–2.4%) by TMLC and 1.3% (0.8–1.9%) by 3DIS. Median interexaminer CV for STU was 13.7% (IQR 8.5–21.3%). The portable imaging system noninvasively provided accurate and reproducible limb volume and circumference measurements in approximately 2 minutes per patient. This portable technology has the potential to greatly improve assessment and monitoring of lymphedema in the clinic and in the field. en_US
dc.language.iso en en_US
dc.publisher ResearchGate en_US
dc.title Use of a Novel Portable Three-Dimensional Imaging System to Measure Limb Volume and Circumference in Patients with Filarial Lymphedema en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account