Determination of measurement uncertainty in chloride analysis in groundwater by APHA 4500Cl- method

Show simple item record

dc.contributor.author Anoja, N.
dc.contributor.author Kunaseelan, S.
dc.date.accessioned 2021-12-17T04:20:44Z
dc.date.available 2021-12-17T04:20:44Z
dc.date.issued 2021-02-17
dc.identifier.issn 1391-8796
dc.identifier.uri http://ir.lib.ruh.ac.lk/xmlui/handle/iruor/4662
dc.description.abstract Testing laboratories must be able to provide reliable results when performing analytical tests for clients or for regulatory purposes. The concept of measurement uncertainty has become important in the area of analytical quality, providing a single measure of accuracy of analytical results. Chloride (Cl−) ion- is one of the major inorganic anions in water and wastewater. Chloride content of the Jaffna district is varying from 200mg/L to 1200mg/L depends on the location of the area. In this study all possible uncertainty sources associated with testing of chloride in groundwater is taken into account. The measurement uncertainty sources are grouped according to input quantities and schematically presented in the form of the so-called “fish-bone” diagram. Sampling and analysis of groundwater chloride is done based on methods stipulated by American Public Health Association (APHA). “A grade” volumetric apparatus were used for the analysis and analytical balance was calibrated by accredited calibration laboratory. The titrant AgNO3 was standardized by the primary standard (NaCl, Normality 0.0141, purity 99.9%). Groundwater samples were collected from various location of Jaffna district and chloride concentration was determined. Uncertainty of standardization of titrant AgNO3, Sample measurement, Volume of titrant AgNO3 are 0.0142, 0.0035, 0.0033 respectively and combined uncertainty is 7.1mg/L for chloride concentration of 473.7mg/L. It was found that 473.7±14.2, K=2, which is around 3% of chloride concentration. The uncertainty associated with standardization of titrant AgNO3 is comparatively high. en_US
dc.language.iso en en_US
dc.publisher Faculty of Science, University of Ruhuna, Matara, Sri Lanka en_US
dc.subject Measurement uncertainty en_US
dc.subject Chloride en_US
dc.subject Standard solution en_US
dc.title Determination of measurement uncertainty in chloride analysis in groundwater by APHA 4500Cl- method en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account